Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
1.
J Am Heart Assoc ; : e032837, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38639355

RESUMO

Evidence from medicine and other fields has shown that gender diversity results in better decision making and outcomes. The incoming workforce of congenital heart specialists (especially in pediatric cardiology) appears to be more gender balanced, but past studies have shown many inequities. Gender-associated differences in leadership positions, opportunities presented for academic advancement, and recognition for academic contributions to the field persist. In addition, compensation packages remain disparate if evaluated based on gender with equivalent experience and expertise. This review explores these inequities and has suggested individual and institutional changes that could be made to recruit and retain women, monitor the climate of the institution, and identify and eliminate bias in areas like salary and promotions.

2.
World J Pediatr Congenit Heart Surg ; 15(1): 37-43, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37551083

RESUMO

Background: National data about the outcomes of children undergoing mechanical mitral valve replacement (m-MVR) are scarce. Methods: A retrospective review of hospitalizations from the Kids' Inpatient Database was performed for patients ≤18 years of age in the United States. A total of 500 patients underwent m-MVR in 2009, 2012, 2016, and 2019. Patients with single ventricle physiology were excluded (n = 13). These patients were categorized into three groups according to age: neonates (<1 month, n = 20), infants (1-12 months, n = 76 patients), and children (1-18 years, n = 404). Outcomes were compared between the three groups. Results: The proportion of m-MVR involving children undergoing MV procedures (repair and replacement) has increased from 17.3% in 2009 to 30.8% in 2019 (Ptrend < .01). History of cardiac surgery was present in 256 patients (51.2%). Concomitant procedures were performed in 119 patients (23.8%). Intra- or postoperative extracorporeal membrane oxygenation was required in 19 patients (3.8%). The overall in-hospital mortality was 4.8% and was significantly higher in neonates and infants compared with older children (10% vs 11.8% vs 3.2%, P = .003). The length of hospital stay was longer in the neonatal group (median, 57 days, interquartile range, [24.8-90] vs 29.5 days [15.5-61] vs 10 days [7-18], P < .01). Nonhome discharges were more common in neonates and infants (40% vs 36.8% vs 13.1%, P < .01). Conclusion: Mechanical mitral valve replacement is increasingly performed over time with acceptable in-hospital morbidity and mortality, especially in older children and adolescents. Neonates and infants are associated with worse hospital survival, prolonged hospitalization, and significant rates of nonhome discharges.


Assuntos
Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Lactente , Recém-Nascido , Adolescente , Humanos , Criança , Estados Unidos/epidemiologia , Doenças das Valvas Cardíacas/cirurgia , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Estudos Retrospectivos , Hospitais , Insuficiência da Valva Mitral/cirurgia
3.
Can J Cardiol ; 39(10): 1358-1365, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37141988

RESUMO

BACKGROUND: Fontan pathway stenosis is a well-known complication after palliation. Percutaneous stenting is effective for angiographic/hemodynamic relief of Fontan obstruction, but its clinical impact in adults remains unknown. METHODS: This was a retrospective cohort of 26 adults undergoing percutaneous stenting for Fontan obstruction from 2014 to 2022. Procedural details, functional capacity, and liver parameters were reviewed at baseline and during follow-up. RESULTS: Median age was 22.5 years (interquartile range [IQR] 19-28.8 y); 69% were male. After stenting, Fontan gradient significantly decreased (2.0 ± 1.9 vs 0 [IQR 0-1] mm Hg; P < 0.005), and minimal Fontan diameter increased (11.3 ± 2.9 vs 19.3 [IQR 17-20] mm; P < 0.001). One patient developed acute kidney injury periprocedurally. During a follow-up of 2.1 years (IQR 0.6-3.7 y), 1 patient had thrombosis of the Fontan stent and 2 underwent elective Fontan re-stenting. New York Heart Association functional class improved in 50% of symptomatic patients. Changes in functional aerobic capacity on exercise testing were directly related to pre-stenting Fontan gradient (n = 7; r = 0.80; P = 0.03) and inversely related to pre-stenting minimal Fontan diameter (r = -0.79; P = 0.02). Thrombocytopenia (platelet count < 150 109/L) was present in 42.3% of patients before and in 32% after the procedure (P = 0.08); splenomegaly (spleen size > 13 cm) was present in 58.3% and 58.8% (P = 0.57), respectively. Liver fibrosis (aspartate transaminase to platelet ratio index and Fibrosis-4) scores were unchanged after the procedure compared with baseline. CONCLUSIONS: Percutaneous stenting in adults is safe and effective in relieving Fontan obstruction, resulting in subjective improvement in functional capacity in some. A subset of patients demonstrated improvement in markers of portal hypertension, suggesting that Fontan stenting could improve Fontan-associated liver disease in select individuals.

4.
JACC Case Rep ; 14: 101830, 2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37077872

RESUMO

A 7-year-old child with native coarctation of the aorta was treated by transcatheter therapy using a 29-mm balloon-expandable stent. The procedure was successful and free of complications, and the patient was discharged home the same day. This stent has several features making it uniquely advantageous for treating this condition. (Level of Difficulty: Advanced.).

5.
Pediatr Cardiol ; 44(5): 1057-1067, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36508019

RESUMO

The evolving breadth and complexity of the contemporary pediatric cardiology specialty requires regular, systematic analysis of the practice to ensure that training and certification requirements address the demands of real-world clinical experience. We report the process of the American Board of Pediatrics (ABP) for conducting such a practice analysis and revising the test content outline (TCO) for the pediatric cardiology subspecialty certification exam. A panel of 15 pediatric cardiologists conducted seven 2-h virtual meetings, during which they identified 37 unique tasks that represent the work a pediatric cardiologist may reasonably expect to perform within the first 5 years after training. These tasks were grouped into nine performance domains, similar to the entrustable professional activities (EPA), previously endorsed by the ABP in collaboration with the pediatric cardiology education community, and which represent the critical activities of the profession. The panel then enumerated the knowledge, skills, and abilities necessary to perform each task. These deliberations resulted in two work products: a practice analysis document (PAD) and subspecialty board TCO based on testable knowledge, skills, and abilities. Survey assessments of the panel's work were then distributed to pediatric cardiology fellowship program directors and to practicing pediatric cardiologists for their input, which largely aligned with the panel's recommendations. Survey responses were considered in the final revisions of the PAD and TCO. This approach to practice analysis proved to be an efficient process for describing the work performed by today's pediatric cardiologists and the knowledge, skills, and abilities needed to competently perform that work.


Assuntos
Cardiologia , Pediatria , Humanos , Estados Unidos , Criança , Certificação , Competência Clínica , Currículo , Cardiologia/educação , Pediatria/educação
9.
Ann Thorac Surg ; 114(3): 826-832, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35149047

RESUMO

BACKGROUND: There are sparse data on outcomes after expanded polytetrafluoroethylene artificial neochordae (ePTFE-AN) for tricuspid valve (TV) repair. We evaluated outcomes after TV repair with ePTFE-AN in both pediatric and adult patients. METHODS: We analyzed clinical data of 87 consecutive patients who underwent ePTFE-AN implantation at the time of TV repair from 1998 to 2020. Patients were categorized into pediatric and adult groups. RESULTS: There were 29 pediatric (33.3%) and 58 adult (66.7%) patients. The most common etiology of tricuspid regurgitation (TR) was congenital (pediatrics: 86.2% [25 of 29]; adults: 39.7% [23 of 59]). The median number of pairs of ePTFE-AN implanted was 2 (interquartile range [IQR], 2-5 pairs) for pediatric and 3 (IQR, 2-4 pairs) for adult patients. There was no early death. Three adult patients (5.2%) required early TV reoperation, and 4 patients (1 pediatric, 3 adults) underwent late TV reintervention. Etiology of TR was congenital in 4 of the 6 adults who required TV reintervention. The 3-year cumulative risk of TV reintervention was 0.0% for pediatric and 7.3% (95% CI, 0.4%-14.2%) for adult patients. There was significant improvement in TR grade after TV repair at dismissal and at the latest echocardiographic follow-up in each group (P < .001). Severe TR developed in 1 pediatric patient and 7 adult patients during follow-up, and 6 (1 pediatric, 5 adults) of them underwent TV reoperation. CONCLUSIONS: ePTFE-AN implantation in the TV position can be performed safely and effectively with no early death. In adult patients with congenital TR, patient selection is critical to achieve a durable outcome after TV repair.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Adulto , Criança , Humanos , Politetrafluoretileno , Estudos Retrospectivos , Resultado do Tratamento , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/cirurgia
10.
Curr Cardiol Rep ; 24(1): 51-58, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-35028814

RESUMO

PURPOSE OF REVIEW: To review the use of covered stents in the treatment of coarctation of the aorta (CoA) and right ventricle to pulmonary artery (RV-PA) conduit obstruction. RECENT FINDINGS: The only commercially available covered stent approved for treatment of CoA and dysfunctional RV-PA conduits is the covered Cheatham-Platinum stent (CCPS). Early outcomes have demonstrated its safety and have suggested its efficacy in treating or preventing aortic wall injury (AWI) or conduit disruption. A recent study of CCPS use for CoA reported a progressive risk of stent fracture over time and a risk of AWI despite the purported protection that the CCPS provides. The use of other covered stents has been reported, but large, systematic studies are lacking. CCPS use may reduce but does not eliminate the risk of conduit disruption or AWI. Structural limitations of the CCPS may predispose it to stent fracture. Access to a broad range of covered stents continues to be an unmet need in the field of congenital interventional cardiology.


Assuntos
Coartação Aórtica , Cardiopatias Congênitas , Humanos , Coartação Aórtica/complicações , Coartação Aórtica/cirurgia , Platina , Artéria Pulmonar , Stents , Resultado do Tratamento
12.
World J Pediatr Congenit Heart Surg ; 13(1): 60-64, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34919479

RESUMO

Background: Isolated anterior mitral valve clefts (MVC) are rare congenital heart defects, and data are limited regarding the natural history and surgical outcomes for such isolated MVCs. Methods: We conducted a retrospective review of patients with congenital MVC who were evaluated at Mayo Clinic in Rochester, Minnesota between 1993 and 2020. Patients were separated into two cohorts: those who underwent surgical repair of the MVC and those who had not yet undergone repair. Baseline and postoperative clinical and echocardiographic data were analyzed. Results: Fourteen patients were included in the nonsurgical cohort and eight patients in the surgical cohort. Surgical repair was via primary median sternotomy (n = 6) or robot-assisted, minimally invasive (n = 2). All cleft repairs were performed by simple suture closure. Intraoperative evaluation of the clefts did not reveal additional structural factors that could account for the mitral regurgitation (MR). At latest follow-up of the surgical cohort, the median grade of MR was 1 (range 0-1), and median left ventricular ejection fraction was 65% (IQR 59%-67%), both similar to the immediate postoperative result. At latest follow-up, all patients in the nonsurgical cohort were NYHA Class 1, and median MR grade was 1. All patients were asymptomatic (NYHA Class 1). Conclusions: Our findings corroborate prior reports that MVC repair is safe and successful and is followed by a low rate of recurrent mitral valve dysfunction. Durable surgical repair of isolated, congenital MVC can be performed safely in select patients. The decision to intervene should be based on the severity of mitral regurgitation and patient symptoms rather than the presence of the MVC alone.


Assuntos
Cardiopatias Congênitas , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
13.
J Pediatr ; 243: 208-213.e3, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34952008

RESUMO

In this survey study of institutions across the US, marked variability in evaluation, treatment, and follow-up of adolescents 12 through 18 years of age with mRNA coronavirus disease 2019 (COVID-19) vaccine-associated myopericarditis was noted. Only one adolescent with life-threatening complications was reported, with no deaths at any of the participating institutions.


Assuntos
COVID-19 , Miocardite , Adolescente , COVID-19/prevenção & controle , Vacinas contra COVID-19/efeitos adversos , Humanos , Miocardite/epidemiologia , Miocardite/etiologia , RNA Mensageiro
14.
Mayo Clin Proc ; 96(5): 1356-1362, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33958063

RESUMO

Patients with patent foramen ovale can manifest in a variety of ways. These presentations and their resolution are discussed in this article.


Assuntos
Forame Oval Patente/diagnóstico , Forame Oval Patente/terapia , Adulto , Idoso , Feminino , Forame Oval Patente/complicações , Humanos , Masculino , Pessoa de Meia-Idade
15.
World J Pediatr Congenit Heart Surg ; 12(3): 367-374, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33942687

RESUMO

OBJECTIVE: To identify risk factors for pediatric mechanical mitral valve replacement (mMVR) to improve management in this challenging population. METHODS: From 1993 to 2019, 93 children underwent 119 mMVR operations (median age, 8.8 years [interquartile range [IQR]: 2.1-13.3], 54.6% females) at our institution. Twenty-six (21.8%) patients underwent mMVR at ≤2 years and 93 (78.2%) patients underwent mMVR at >2 years. Median follow-up duration was 7.6 years [IQR: 3.2-12.4]. RESULTS: Early mortality was 9.7%, but decreased with time and was 0% in the most recent era (13.9% from 1993 to 2000, 7.3% from 2001 to 2010, 0% from 2011 to 2019, P = .04). It was higher in patients ≤2 years compared to patients >2 years (26.9% vs 2.2%, P < .01). On multivariable analysis for mitral valve reoperation, valve size <23 mm was significant with a hazard ratio of 5.38 (4.87-19.47, P = .01);. Perioperative stroke occurred in 1% and permanent pacemaker was necessary in 12%. Freedom from mitral valve reoperation was higher in patients >2 years and those with a prosthesis ≥23 mm. Median time to reoperation was 7 years (IQR: 4.5-9.1) in patients >2 years and 3.5 years (IQR: 0.6-7.1) in patients ≤2 years (P = .0511), but was similar between prosthesis sizes (P = .6). During follow-up period (median 7.6 years [IQR: 3.2-12.4], stroke occurred in 10%, prosthetic valve thrombosis requiring reoperation in 4%, endocarditis in 3%, and bleeding in 1%. CONCLUSION: Early and late outcomes of mMVR in children are improved when performed at age >2 years and with prosthesis size ≥23 mm. These factors should be considered in the timing of mMVR.


Assuntos
Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Criança , Pré-Escolar , Feminino , Seguimentos , Doenças das Valvas Cardíacas/cirurgia , Humanos , Masculino , Valva Mitral/cirurgia , Reoperação , Resultado do Tratamento
16.
Catheter Cardiovasc Interv ; 97(4): E502-E509, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33016648

RESUMO

OBJECTIVES: The purpose of this study was to investigate the influence of simulated reduced-dose three-dimensional angiography (3DA) on the accuracy and precision of linear measurements derived from 3DA datasets. BACKGROUND: Three-dimensional angiography is performed during X-ray guided interventional procedures to aid diagnosis and inform treatment strategies for children and adults with congenital heart disease. However, 3DA contributes substantially to patient radiation dose and may lead to an increased radiation-induced cancer risk. METHODS: Reduced-dose patient 3DA images were simulated by adding quantum noise to the 2D projection angiograms, then reconstructing the projection angiograms into the 3DA dataset. Dose reduction in the range 33-72% was simulated. Five observers performed 46 vessel diameter measurements along prespecified axes within 23 vessel segments from 11 patient 3DA datasets. Statistical tests were performed to assess the influence of radiation dose reduction on the accuracy and precision of vessel diameter measurements. RESULTS: Vessel diameter measurements were in the range 5.9- 22.7 mm. Considering all vessel segments and observers, the influence of dose level on the accuracy of diameter measurements was in the range 0.02 - 0.15 mm (p .05-.8). Interobserver variability increased modestly with vessel diameter, but was not influence by dose level (p = .52). The statistical test for observer recall bias was negative (p = .51). CONCLUSIONS: Simulated dose reduction up to 72% did not affect the accuracy or precision of the diameter measurements acquired from 3DA images. These findings may embolden 3DA radiation dose reduction for pediatric and congenital heart disease patients.


Assuntos
Cardiologia , Redução da Medicação , Adulto , Angiografia Digital , Criança , Humanos , Imageamento Tridimensional , Resultado do Tratamento
18.
CJC Open ; 2(3): 129-134, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32462126

RESUMO

BACKGROUND: Inferior vena cava (IVC) size and collapsibility provide a noninvasive estimate of right heart filling pressures, an important determinant of right heart hemodynamic performance that is not measured by cardiac magnetic resonance imaging (CMRI). We hypothesized that compared with CMRI risk model alone, a combined CMRI-IVC risk model will have better correlation with disease severity and peak oxygen consumption in patients with tetralogy of Fallot (TOF). METHODS: We performed a retrospective review of patients with TOF with moderate/severe pulmonary regurgitation who underwent CMRI and echocardiography. A CMRI risk model was constructed using right ventricular (RV) end-diastolic volume index, RV end-systolic volume index, RV ejection fraction, and left ventricular ejection fraction. We added IVC hemodynamic classification to the CMRI indices to create CMRI-IVC risk model, and IVC hemodynamics were modeled as a categorical variable: normal vs mild/moderately abnormal (dilated IVC or reduced collapsibility) vs severely abnormal IVC hemodynamics (dilated IVC and reduced collapsibility). We defined disease severity as atrial arrhythmias, ventricular arrhythmias, and heart failure hospitalization. RESULTS: Of 207 patients, 131 (63%), 72 (35%), and 4 (2%) had normal, mild/moderately abnormal, and severely abnormal IVC hemodynamics, respectively. Compared with the CMRI risk model, the CMRI-IVC risk model had a better correlation with disease severity (area under the curve, 0.62; 95% confidence interval, 0.51-0.74 vs area under the curve 0.84, 95% confidence interval, 0.78-0.91, P = 0.006) and peak oxygen consumption (r = 0.35, P = 0.042 vs r = 0.43, P = 0.031, Meng test P = 0.026). CONCLUSIONS: The combined CMRI-IVC risk model had a better correlation with disease severity compared with CMRI indices alone and can potentially improve risk stratification in the population with TOF.


CONTEXTE: Le diamètre et la collapsibilité de la veine cave inférieure (VCI) permettent d'estimer de façon non invasive les pressions de remplissage du cœur droit, un déterminant important de la capacité hémodynamique cardiaque droite que ne mesure pas l'imagerie par résonance magnétique cardiaque (IRMC). Notre hypothèse était que, comparativement au modèle de risque IRMC seul, un modèle de risque combiné IRMC-VCI présenterait une meilleure corrélation avec la gravité de la maladie et la consommation maximale d'oxygène chez les patients atteints de la tétralogie de Fallot (TF). MÉTHODOLOGIE: Nous avons effectué une étude rétrospective de cas de TF avec régurgitation pulmonaire modérée ou sévère où les patients ont subi un examen d'IRMC et une échocardiographie. Nous avons créé un modèle de risque IRMC intégrant l'indice du volume télédiastolique ventriculaire droit, l'indice du volume télésystolique ventriculaire droit, la fraction d'éjection ventriculaire droite et la fraction d'éjection ventriculaire gauche. Nous avons ajouté une classification hémodynamique de la VCI aux indices d'IRMC pour créer le modèle de risque IRMC-VCI, et les caractéristiques hémodynamiques de la VCI ont été modélisées en tant que variable nominale : état normal vs anomalie légère ou modérée (VCI dilatée ou collapsibilité réduite) vs anomalie sévère des caractéristiques hémodynamiques de la VCI (VCI dilatée et collapsibilité réduite). Nous avons défini la gravité de la maladie en distinguant les arythmies auriculaires, les arythmies ventriculaires et l'insuffisance cardiaque entraînant une hospitalisation. RÉSULTATS: Au sein d'un groupe de 207 patients, les caractéristiques hémodynamiques de la VCI présentaient un état normal, une anomalie légère ou modérée et une anomalie sévère dans 131 cas (63 %), 72 cas (35 %) et 4 cas (2 %), respectivement. Comparativement au modèle de risque IRMC, le modèle de risque IRMC-VCI a présenté une meilleure corrélation avec la gravité de la maladie (aire sous la courbe = 0,62 et intervalle de confiance à 95 % = 0,51-0,74 vs aire sous la courbe = 0,84 et intervalle de confiance à 95 % = 0,78-0,91, p = 0,006) et avec la consommation maximale d'oxygène (r = 0,35, p = 0,042 vs r = 0,43, p = 0,031, p = 0,026 pour le test de Meng). CONCLUSIONS: Le modèle de risque combiné IRMC-VCI a présenté une meilleure corrélation avec la gravité de la maladie comparativement aux indices d'IRMC seuls. Il pourrait améliorer la stratification du risque au sein de la population atteinte de la TF.

19.
Can J Cardiol ; 36(9): 1491-1498, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32247704

RESUMO

BACKGROUND: Elevated pulmonary artery wedge pressure (PAWP) is the hallmark of left-heart failure and is responsible for heart failure symptoms and mortality. Although PAWP typically correlates with right atrial pressure (RAP), it is primarily dependent on left-heart myocardial properties and volume status. As right-heart disease can occur in the absence of left-heart disease in patients with tetralogy of Fallot (TOF), we hypothesized that RAP was the primary determinant of PAWP in this population. METHODS: A cohort study of adults with TOF that underwent right-heart catheterization at Mayo Clinic Rochester (1990 to 2017) to determine the relationship among RAP, PAWP, and mortality. RESULTS: Among 213 patients (male 105; age 37 ± 14 years), the mean PAWP was 14 ± 5 mm Hg, and RAP was 11 ± 5 mm Hg. RAP was the strongest predictor of PAWP (ß = 0.68, standard error = 0.06, P < 0.001), independent of left-heart disease and atherosclerotic cardiovascular risk factors. The patients with high PAWP also had normal tissue Doppler velocities, suggesting normal left-ventricular myocardial properties. PAWP was an independent predictor of death/transplant (hazard ration [HR] 1.11, 95% confidence interval [CI], 1.03-1.20, P = 0.004). However, when RAP was incorporated into the regression model, RAP (and not PAWP) became the independent predictor of outcomes (HR 1.14, 95% CI, 1.06-1.22, P = 0.001). CONCLUSIONS: The current study showed that RAP was the primary determinant of PAWP and accounts, to some extent, for the mortality in patients with TOF and high PAWP. The data provide new insight in the pathophysiology of disease progression for symptomatic patients with TOF.


Assuntos
Ventrículos do Coração/fisiopatologia , Pressão Propulsora Pulmonar/fisiologia , Volume Sistólico/fisiologia , Tetralogia de Fallot/fisiopatologia , Função Ventricular Esquerda/fisiologia , Pressão Ventricular/fisiologia , Adulto , Cateterismo Cardíaco , Feminino , Seguimentos , Humanos , Masculino , Prognóstico , Estudos Retrospectivos
20.
JACC Cardiovasc Imaging ; 13(9): 1863-1872, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32199847

RESUMO

OBJECTIVES: The purpose of this retrospective cohort study was to compare remodeling of left ventricular (LV) structure and function after transcatheter stent therapy with remodeling of LV structure and function after surgical therapy for COA. BACKGROUND: Transcatheter stent therapy is as effective as surgery in producing acute hemodynamic improvement in patients with coarctation of aorta (COA). However, LV remodeling after transcatheter COA intervention has not been systematically investigated. METHODS: LV remodeling was assessed at 1, 3, and 5 years post-intervention by using LV mass index (LVMI), LV end-diastolic dimension, LV ejection fraction, LV global longitudinal strain (LVGLS), LV mitral annular tissue Doppler early velocity (LVe'), and ratio of mitral inflow pulsed wave Doppler early velocity and e' (E/e') ratio. RESULTS: There were 44 patients in the transcatheter group and 128 patients in the surgical group. Compared to the surgical group, the transcatheter group had less regression of LVMI (-4.6; 95% confidence interval [CI]: -5.5 to -3.7 vs. -7.3; 95% CI: -8.4 to -6.6 g/m2; p < 0.001), less improvement in LVGLS (2.1; 95% CI: 1.8 to 2.4 vs. 2.9; 95% CI: 2.6 to 3.2%; p = 0.024), and in e' (1.0 ; 95% CI: 0.7 to 1.2 vs. 1.5 ; 95% CI: 1.3 to 1.7 cm/s; p = 0.009) at 5 years post-intervention. Exploratory analysis showed a correlation between change in LVMI and LVGLS, and between change in LVMI and mitral annular tissue Doppler early velocity (e'), and this correlations were independent of the type of intervention received. CONCLUSIONS: Transcatheter stent therapy was associated with less remodeling of LV structure and function during mid-term follow-up. As transcatheter stent therapy becomes more widely used in the adult COA population, there is a need for ongoing clinical monitoring to determine if these observed differences in LV remodeling translate to differences in clinical outcomes.


Assuntos
Coartação Aórtica , Disfunção Ventricular Esquerda , Adolescente , Adulto , Antagonistas de Receptores de Angiotensina , Inibidores da Enzima Conversora de Angiotensina , Diástole , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Função Ventricular Esquerda , Remodelação Ventricular , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...